Copyright © Luohe Bingyang Refrigeration Equipment Co., Ltd. All Rights Reserved. Site Map
MAIN TECHNICAL SPECIFICATION | ||
Unit Type | BY-600 | |
Temperature range | -25°C/+30°C | |
Applicable compartment volume (m³) | 18-26m³ | |
Cooling capacity(w) | 0°C/+30°C | 5530 |
-18°C /+30°C | 3015 | |
Refrigerant/charge amount (KG) | R404A/2.2 | |
Compressor | Model | TM16 |
(POE) Refrigeration oil | RL68H | |
Condenser | Condenser material | Parallel Flow |
Fan air volume (100pa static pressure unit m³/h | 2200m³/h/tower | |
Fan quantity/model | 2/261 Suction | |
Evaporator | Evaporator material | Copper tube fin |
Fan air volume (100pa static pressure unit m³/h) | 950m³/h/tower | |
Fan quantity/model | 3/2209 Blow | |
Condensation and evaporation integrated assembly | Dimensions (mm) | 1605×560×575 |
Weight (KG) | 76kg | |
Defrost mode | Hot air defrost | |
Heating (yes/no) | Yes | |
Drive mode | Engine direct drive |
|
Backup power 220V AC (optional) |
| |
Unit voltage | direct current | 12V/24V |
Note: 1. The applicable compartment volume is for production reference only. The actual usage volume is related to the compartment insulation performance (insulation compartment heat leakage coefficient K=0.32Watts/m℃), usage environment, and cargo.
2. The above data and product appearance are subject to change without prior notice. The corresponding actual model shall prevail. |